2022-05-09 Fertilizer Application Fertilize east 30' of IP3 camelina with 41 lbs. N/A. Fertilize B0 north extra oats with 30 lbs. N/A.

2022-05-09 Fertilizer Application Fertilize east 30' of IP3 camelina with 41 lbs. N/A. Fertilize B0 north extra oats with 30 lbs. N/A.

2008-06-20 Mechanical Weed Control Sprayed the GLBRC Main Site, G-4 Canola plot replications 1-5, for weed control. Roundup OriginalMax (glyphosate) was applied at 22 ounces/acre (1.6 L/ha) with Ammonium Sulfate 17 lbs / 100 gallons (3.4 lbs/acre; 3.82 kg/ha). Weather conditions: Partly cloudy with air temperature of 79 degrees F (26.1°C). Relative Humidity was 61%. Wind was calm. Time of application was 8:00 a.m. Equipment Used: JD 5320 tractor traveling 5 mph (gear C1, 1650 rpm) with a 3-point mounted sprayer with a rolling pump (Dempco). Turbo TeeJet 8002 nozzles were used, spaced 15 inches apart with a total boom length of 15 feet. 30 psi was used. Water applied at 20 gallons/acre (187L/ha) was used as the carrier. Purpose of application: Burn down of grasses, broadleaves in canola plots.

2008-06-17 Mechanical Weed Control Sprayed the GLBRC Main Site, G-3 Roundup Ready Soybean plots replications 1-5, for weed control. Roundup OriginalMax (glyphosate) was applied at 22 ounces/acre (1.6 L/ha) with Ammonium Sulfate 17 lbs / 100 gallons (3.4 lbs/acre; 3.82 kg/ha). Weather conditions: Partly cloudy with air temperature of 57 degrees F (13.9°C). Relative Humidity was 36%. Wind was calm. Time of application was 9:00 a.m. Equipment Used: JD 5320 tractor traveling 5 mph (gear C1, 1650 rpm) with a 3-point mounted sprayer with a rolling pump (Dempco). Turbo TeeJet 8002 nozzles were used, spaced 15 inches apart with a total boom length of 15 feet. 30 psi was used. Water applied at 20 gallons/acre (187L/ha) was used as the carrier. Purpose of application: Burn down of grasses, broadleaves in soybean plots.

2008-06-25 Herbicide Application Sprayed the LTER Main Site, Cellulosic Biofuels Study, all treatments and all replications for preemergence weed control. Lexar (S-metolachlor (+ safener) + atrazine + mesotrione) was broadcast sprayed at 3 qts/acre (7.1 L/ha). Weather conditions: Partly cloudy with air temperature of 68 degrees F (20.0°C). Relative Humidity was 50%. Wind was calm. Time of application was 10:00 a.m. Equipment Used: JD 5320 tractor traveling 5 mph (gear C1, 1650 rpm) with a 3-point mounted sprayer with a rolling pump (Dempco). Turbo TeeJet 8002 nozzles were used, spaced 15 inches apart with a total boom length of 15 feet. 30 psi was used. Water applied at 20 gallons/acre (187L/ha) was used as the carrier. Purpose of application: Pre-emergence herbicide application.

2008-06-03 Mechanical Weed Control Sprayed the LTER Main Site, Cellulosic Ethanol Study [Bio-fuels study] for weed control. Roundup OriginalMax (glyphosate) was applied at 1 quart/acre (2.3 L/ha) with Ammonium Sulfate 17 lbs / 100 gallons (3.4 lbs/acre; 3.82 kg/ha). Weather conditions: Partly cloudy with air temperature of 60 degrees F (15.6°C). Relative Humidity was 40%. Wind was from the northwest at 7 mph. Time of application was 11:00 a.m. Equipment Used: JD 5320 tractor traveling 5 mph (gear C1, 1650 rpm) with a 3-point mounted sprayer with a rolling pump (Dempco). Turbo TeeJet 8002 nozzles were used, spaced 15 inches apart with a total boom length of 15 feet. 30 psi was used. Water applied at 20 gallons/acre (187L/ha) was used as the carrier. Purpose of application: Burn down of grasses and broadleaves.

2008-06-11 Mechanical Weed Control Sprayed the LTER Main Site, Treatment 5, replications 1, 2, 3, 4, 5, and 6 for weed control. Roundup OriginalMax (glyphosate) was applied at 1 quart/acre (2.3 L/ha) with 2,4-D ester (2,4-D) at 1 pt/acre (1.17 L/ha) and Ammonium Sulfate 17 lbs / 100 gallons (3.4 lbs/acre; 3.82 kg/ha). Weather conditions: Partly cloudy with air temperature of 75 degrees F (23.9°C). Relative Humidity was 59%. Wind was from the west at 5 mph. Time of application was 4:00 p.m. Equipment Used: JD 5320 tractor traveling 5 mph (gear C1, 1650 rpm) with a 3-point mounted sprayer with a rolling pump (Dempco). Turbo TeeJet 8002 nozzles were used, spaced 15 inches apart with a total boom length of 15 feet. 30 psi was used. Water applied at 20 gallons/acre (187L/ha) was used as the carrier. Purpose of application: Burn down of grasses, broadleaves and poplar tree growth.

2008-05-15 Mechanical Weed Control Sprayed the LTER Main Site, Treatment 3, replications 1-6, for preemergence weed control. Lexar (S-metolachlor (+ safener) + atrazine + mesotrione) was band sprayed at 3 qts/acre (7.1 L/ha) in the sprayed bands. Weather conditions: Partly cloudy with air temperature of 67 degrees F (19.4°C). Relative Humidity was 52%. Wind was calm. Time of application was 6:00 p.m. Equipment Used: JD 5320 tractor traveling 5 mph (gear C1, 1650 rpm) with a 3-point mounted sprayer with a rolling pump (Dempco). Turbo TeeJet 8002 nozzles were used, spaced 15 inches apart with a total boom length of 15 feet; bands were 10 inches wide (25.4 cm) over each of six rows at a time. 30 psi was used. Water applied at 20 gallons/acre (187L/ha) was used as the carrier. Purpose of application: Pre-emergence herbicide application.

2008-05-09 Herbicide Application Sprayed the LTER Main Site, Treatment 1, replications 2, 3, 4, and 6 were sprayed on May 9, 2008. T1 reps 1 and 5 were sprayed on May 10, 2008. The purpose for the application was preemergence weed control. Lexar (S-metolachlor (+ safener) + atrazine + mesotrione) was applied at 3 qts/acre (7.1 L/ha). May 9, 2008 weather conditions: Partly cloudy with air temperature of 54 degrees F (12.2°C). Relative Humidity was 35%. Wind was out of south at 5-7 mph averaging 6 mph. Time of application was 9:00 a.m. Equipment Used: JD 5320 tractor traveling 5 mph (gear C1, 1650 rpm) with a 3-point mounted sprayer with a rolling pump (Dempco). Turbo TeeJet 8002 nozzles were used, spaced 15 inches apart with a total boom length of 15 feet. 30 psi was used. Water applied at 20 gallons/acre (187L/ha) was used as the carrier. Purpose of application: Pre-emergence herbicide application. G1, G2, and GLBRC boarder rows were sprayed on May 9, 2008.

2008-05-14 Mechanical Weed Control Sprayed the LTER Main Site, Treatment 2, replications 1-6, for preemergence weed control. Lexar (S-metolachlor (+ safener) + atrazine + mesotrione) was applied at 3 qts/acre (7.1 L/ha). Weather conditions: Partly cloudy with air temperature of 52 degrees F (11.1°C). Relative Humidity was 32%. Wind was out of south at 5 mph. Time of application was 9:00 a.m. Equipment Used: JD 5320 tractor traveling 5 mph (gear C1, 1650 rpm) with a 3-point mounted sprayer with a rolling pump (Dempco). Turbo TeeJet 8002 nozzles were used, spaced 15 inches apart with a total boom length of 15 feet. 30 psi was used. Water applied at 20 gallons/acre (187L/ha) was used as the carrier. Purpose of application: Pre-emergence herbicide application.

2008-08-12 Mechanical Weed Control Sprayed the LTER Main Site, Treatment 6 replications 1-6. Roundup OriginalMax (glyphosate) was applied at 22 ounces/acre (1.6 L/ha) with Ammonium Sulfate 17 lbs / 100 gallons (3.4 lbs/acre; 3.82 kg/ha). Weather conditions: Partly cloudy with air temperature of 69 degrees F (20.6°C). Relative Humidity was 53%. Wind was calm. Time of application was 5:00 p.m. Equipment Used: JD 5320 tractor traveling 5 mph (gear C1, 1650 rpm) with a 3-point mounted sprayer with a rolling pump (Dempco). Turbo TeeJet 8002 nozzles were used, spaced 15 inches apart with a total boom length of 15 feet. 30 psi was used. Water applied at 20 gallons/acre (187L/ha) was used as the carrier. Purpose of application: Burn down of grasses and broadleaves.

2008-05-09 Herbicide Application Sprayed for the LTER Main Site, Treatment 8, corn, crop area only for weeds. Roundup Original Max 5.5L (glyphosate) was applied at 22 oz/A (1.6 L/ha) with 2,4-D ester (2,4-D) at 1 pt/acre (1.17 L/ha) and AMS (ammonium sulfate) 17 lbs/100 gals of water (3.4 lbs/acre; 3.82 kgha)were applied. Weather Conditions: at 10:00 a.m. Partly cloudy with air temperature of 49 degrees F (9.4°C). Relative Humidity was 46%. Wind was out of the northeast at 6 mph's averaging 6 mph's. Time of application was 10:00 a.m. Equipment Used: JD 5320 tractor traveling 5 mph(gear C1, 1650 rpm) with a 3-point mounted sprayer with a rolling pump (Dempco). Turbo TeeeJet 8002 nozzles were used, spaced 15 inches apart with a total boom length of 15 feet. 30 psi was used. Water applied at 20 gals/A, (187L/ha), was used as the carrier. Purpose of Application: Burndown of grasses and broadleaves in crop area.

2008-05-15 Mechanical Weed Control Sprayed the LTER Main Site, Treatment8 NT (4 plots), for preemergence weed control. Lexar (S-metolachlor (+ safener) + atrazine + mesotrione) was applied at 3 qts/acre (7.1 L/ha). Weather conditions: Partly cloudy with air temperature of 42 degrees F (5.6°C). Relative Humidity was 32%. Wind was not detectable at time of application. Time of application was 9:00 a.m. Equipment Used: JD 5320 tractor traveling 5 mph (gear C1, 1650 rpm) with a 3-point mounted sprayer with a rolling pump (Dempco). Turbo TeeJet 8002 nozzles were used, spaced 15 inches apart with a total boom length of 15 feet. 30 psi was used. Water applied at 20 gallons/acre (187L/ha) was used as the carrier. Purpose of application: Pre-emergence herbicide application.

2008-06-06 Mechanical Weed Control Sprayed the LTER Main Site, Lysimeter field, east 2/3 of field due to crabgrass emergence with preemergence weed control. Lexar (S-metolachlor (+ safener) + atrazine + mesotrione) was applied at 1 1/2 qts/acre (3.5 L/ha). Weather conditions: Partly cloudy with air temperature of 57 degrees F (13.9°C). Relative Humidity was 48%. Wind was from the north west at 7 mph. Time of application was 10:00 a.m. Equipment Used: JD 5320 tractor traveling 5 mph (gear C1, 1650 rpm) with a 3-point mounted sprayer with a rolling pump (Dempco). Turbo TeeJet 8002 nozzles were used, spaced 15 inches apart with a total boom length of 15 feet. 30 psi was used. Water applied at 20 gallons/acre (187L/ha) was used as the carrier. Purpose of application: Pre-emergence herbicide application for crabgrass control.

2008-05-29 Mechanical Weed Control Sprayed the LTER Main Site, Lysimeter field, for preemergence weed control. Lexar (S-metolachlor (+ safener) + atrazine + mesotrione) was applied at 3 qts/acre (7.1 L/ha). Weather conditions: Partly cloudy with air temperature of 69 degrees F (20.6°C). Relative Humidity was 55%. Wind was calm. Time of application was 6:00 p.m. Equipment Used: JD 5320 tractor traveling 5 mph (gear C1, 1650 rpm) with a 3-point mounted sprayer with a rolling pump (Dempco). Turbo TeeJet 8002 nozzles were used, spaced 15 inches apart with a total boom length of 15 feet. 30 psi was used. Water applied at 20 gallons/acre (187L/ha) was used as the carrier. Purpose of application: Pre-emergence herbicide application.

2008-05-15 Mechanical Weed Control Sprayed the LTER Main Site, Nitrogen rate study, for preemergence weed control. Lexar (S-metolachlor (+ safener) + atrazine + mesotrione) was applied at 3 qts/acre (7.1 L/ha). Weather conditions: Partly cloudy with air temperature of 52 degrees F (11.1°C). Relative Humidity was 45%. Wind was from the west at 5 mph. Time of application was 12:00 noon. Equipment Used: JD 5320 tractor traveling 5 mph (gear C1, 1650 rpm) with a 3-point mounted sprayer with a rolling pump (Dempco). Turbo TeeJet 8002 nozzles were used, spaced 15 inches apart with a total boom length of 15 feet. 30 psi was used. Water applied at 20 gallons/acre (187L/ha) was used as the carrier. Purpose of application: Pre-emergence herbicide application.

2008-11-01 Herbicide Application Sprayed the LTER Main Site, Treatment 5 replications 1-6. Roundup (glyphosate) was applied at ? ounces/acre (? L/ha) with Ammonium Sulfate 17 lbs / 100 gallons (3.4 lbs/acre; 3.82 kg/ha). Weather conditions: ? with air temperature of ? degrees F (? °C). Relative Humidity was ?. Wind was ?. Time of application was ? Equipment Used: JD 5320 tractor traveling ? mph (gear ?, ? rpm) with a 3-point mounted sprayer with a rolling pump (Dempco). Turbo TeeJet ? nozzles were used, spaced 15 inches apart with a total boom length of 15 feet. ? psi was used. Water applied at ? gallons/acre (? L/ha) was used as the carrier. Purpose of application: Burn down of grasses and broadleaves.

2008-11-01 Herbicide Application Sprayed the LTER Main Site, Treatment 6 replications 1-6. Roundup (glyphosate) was applied at ? ounces/acre (? L/ha) with Ammonium Sulfate 17 lbs / 100 gallons (3.4 lbs/acre; 3.82 kg/ha). Weather conditions: ? with air temperature of ? degrees F (? °C). Relative Humidity was ?. Wind was ?. Time of application was ? Equipment Used: JD 5320 tractor traveling ? mph (gear ?, ? rpm) with a 3-point mounted sprayer with a rolling pump (Dempco). Turbo TeeJet ? nozzles were used, spaced 15 inches apart with a total boom length of 15 feet. ? psi was used. Water applied at ? gallons/acre (? L/ha) was used as the carrier. Purpose of application: Burn down of grasses and broadleaves.

2009-05-26 Mechanical Weed Control

2009-07-24 Mechanical Weed Control

2009-05-05 Fertilizer Application 45 acres on the monitor.

2009-07-03 Fertilizer Application Time reflects road travel and spray time

2010-05-04 Fertilizer Application

2010-04-30 Mechanical Weed Control

2010-04-30 Mechanical Weed Control

2011-05-06 Mechanical Weed Control

2011-05-13 Mechanical Weed Control

2011-06-15 Fertilizer Application sprayed north east corner from old feed bunk south to just south of sod waterway to the east edge,and one sprayer width on west side of field to the sod waterway on the big hill

2012-05-07 Mechanical Weed Control applied herbicide with Demco 'Starquest' Sprayer Lumax per qt 2.500 Qt Atrazine per Qt 0.500 Qt Gramoxone Inteon 2.000 Pint Preference surfactant 2.350 Oz

2012-05-06 Mechanical Weed Control After planting.

2021-07-30 Herbicide Application Spray Buccaneer Plus to control weeds before cover crop emergence. REI ends 7/31/2021 at 3:00 a.m.

2021-05-04 Herbicide Application T2 & T3 planting green soy beans in rye.