Show Observation
User: Peter Hudy
Created on: 2012-05-14
Observation Date 2012-05-11
Comment:
Sprayed the LTER Main Site Treatments T8nt (no till component of treatment T8) all replications, for preplant burndown weed control using Roundup PowerMax and ammonium sulfate. Roundup Power Max (EPA Reg. No. 524-549) (Glyphosate: N-(phosphonomethyl) glycine, in the form of its potassium salt, 48.7%) was applied at 1 qt/acre, and Ammonium Sulfate (sprayable, CAS #7783-20-2) was applied at 3.4 lbs/acre. Weather conditions: Sunny with air temperature of 56 degrees F. Relative Humidity was 52%. Wind was from calm and from north at 0-2 mph. Time of application was 10:00 - noon. Equipment Used: JD 5220 tractor traveling 3.8 mph (gear B3, 1700 rpm) with a pull type Top Air Sprayer equipped with a hydraulic centrifugal sprayer pump and a Raven 440 automatic carrier control unit. Turbo TeeJet 11003 nozzles were used, spaced 15 inches apart with a total boom length of 30 feet. 20 psi were used. Water applied at 20 gals/A, (187 L/ha), was used as the carrier.
Areas:
T8nt
Observation Type:
Herbicide Application
Activities:
Attachments: