Show Observation
User: Peter Hudy
Created on: 2009-06-24
Observation Date 2009-06-22
Comment:
Sprayed the LTER main site, treatment 6, replications 1-6, for preplant weed burndown. Roundup Original Max 5.5L (gyphosate) was applied at 22 ounces/acre (0.65 L/ha) with 17 pounds/100 gallons sprayable ammonium sulfate. Weather conditions: Sunny with air temperature of 83-85 degrees F (28-29°C). Relative Humidity was 55%. Wind was from ESE at 6 mph. Time of application was 4:30 p.m. Equipment Used: JD 5220 tractor traveling 4.8 mph (gear C1, 1550 rpm) with a pull type Top Air Sprayer equipped with a hydraulic centrifugal sprayer pump and a Raven 440 automatic carrier control unit. Turbo TeeJet 11003 nozzles were used, spaced 15 inches apart with a total boom length of 30 feet. 20-30 psi were used. Water applied at 20 gals/A, (187 L/ha), was used as the carrier.
Areas:
T6
Observation Type:
Mechanical Weed Control
Activities:
Attachments: